Glow in the dark exit signs requirements: everyone in the workplace must know the relevant fire safety information, so that in case of fire or other disasters, employees can escape in time. In terms of fire safety signs, this means that everyone must know the location of fire alarm and emergency equipment, understand the location of fire channel and how to enter safely.

In the past, it has been proved that export signs can save life. In the event of a fire, keep a calm mind and find the nearest emergency exit to ensure the greatest chance of escape. It is easier to complete with the help of the exit sign. Safety export marking is very useful and is considered mandatory in any facility. More importantly, there are strict regulations on what exit signs are required. In most cases, the glow in the dark exit signs are cheap, effective and fully consistent with all safety specifications and regulations.

Glow In The Dark Exit Signs

Photoluminescent Safety Signs Seven Major Advantages: light long time, low energy consumption, simple installation, long life, easy to maintain, environmental protection, high reliability.

The individual requirements for fire safety signs in your workplace will be decided by personal risk assessment of your business. However, the following concise guidelines for fire safety signs introduce the main safety signs, and indicate which circumstances you should use.

What is a fire safety sign?

Fire safety signs are used to provide health and safety information to warn of danger, to provide instructions, or to provide you with safety information. Security signs can be a variety of colors – usually red, green, yellow or blue, and may contain images, words or a mixture of both. It is very important to observe the fire safety signs in the workplace and any other public places: they are at your side for your safety, and neglect they will have serious consequences.

Why is the fire safety sign important?

In 2005, management reform (fire safety) decree stipulates that all workplaces must have enough safety signs to instruct people to fire equipment, emergency routes and emergency exits.

The American Occupational Safety and Health Administration (OSHA) defines the export route as a safe place from any location in the workplace to an emergency. This includes all exportation, export, export or aisle, from export to public passageway or other security areas.

This legal requirement is crucial, because there is no proper sign, and you may put your employee’s life in danger. According to the health and safety law, all employers have legal responsibilities to ensure their health and safety at work: fire safety signs are only one of the many things that can be done to comply with this requirement.

Glow in the dark exit signs design requirements:

Exit signs must have a clear and readable letter “EXIT”, which is at least 6 inches, and the stroke width (the width of the letter) is at least 3/4 inches. Signs and letters must be unique colors that provide a high contrast between the letters and the background.

There are some temporary exit signs, usually just printed on a piece of paper. Because of the lack of visibility, these are unacceptable. In order to make the exit sign effective, it must be able to see the exit signs in emergency cases, such as fire. Glow in the dark exit sign is the best solution, because it doesn’t need power supply, and luminous exit signs can shine through the absorption of visible light when the light is insufficient. Please refer to the luminous principle of glow film: Glow Film

What is the regulation of glow in the dark fire safety signs?

The following “1996 health and safety (safety signs and signals)” Regulations on fire safety signs provide some guidance, indicating what signs should be used, and how and where to install them.

  • Fire safety signs should always be clear and clear – ensure the use of fire safety signs to clearly and effectively indicate the escape route and to export in the event of a fire.
  • The escape routes and doors must be marked clearly. Any door confusing with the emergency exit door should be marked with clear signs or notices, or signs or notifications as “no export” or “no way out” or marked “storehouse”.
  • The signs for escape routes must be displayed along the export routes, which should be changed in all directions of corridors, staircases, open spaces, and all doors or intersections.
  • Fire safety signs should be lit – so that they can always be seen and clearly visible, including in the case of power loss.
  • The direction arrow is included in the escape route sign to indicate the fastest way to safety. Wherever you are, you can see the nearest escape route sign immediately. Each flag contains the direction arrow, pointing to a more effective route.
  • The final export fire signs should not have arrows – the emergency exit signs above the exit gate should not have arrows. Instead, they should be replaced by the image of a running person, or simply “quit” or “quit”.
  • Don’t mix signs – stick to all European standard signs or all British standard signs: don’t mix the two.
  • It is recommended that the fire safety instructions be supplemented with the form of pictures. The signs must be suitable for all users, including those with poor eyesight, who are suffering from dyslexia or no English as the first language. The supplementary text will also ensure that the meaning of the graphic symbol is fully understood. The disability discrimination act further stipulates that the disabled must make “reasonable adjustments”, including displaying braille and tactile fire safety signs beside the standard picture signs.
  • The sign should be placed at the right height – the sign needs to be visible far away (the British Standard Association can find complete guidance in the BS 5499 fourth section). The sign on the door should be 2 meters away from the ground, or below 2 meters from the ceiling, and the mark on the wall should be 1.7 meters away from the ground.
  • The enterprise should introduce the different fire extinguishers in the workplace to the employees – the diagrams of different types of fire extinguishers and information about the 6 categories of fire symbols.
  • All employees should know the location of the nearest fire alarm and how to do it in case of emergency. This is a legitimate requirement, and we can use trainers to use the “fire alarm point” sign and show the location of the fire operation notice.
  • Fire equipment must mark signs – for example, a sign indicating the position of a fire hose reel or fire extinguisher.

Display of export signs:

The export signs of each person must be clearly marked. In addition, if the export route of a particular working area is not immediately apparent, a sign must be posted on the route to indicate the direction of the export.

If the exit or passageway of export passageway cannot go to the exit, it may be mistaken for export. It must be clearly marked “not exported” or marked with the purpose of indicating the purpose of the area, which clearly indicates that this is not an export.

Exit signs must be placed in clearly visible areas, with clear lines from any working area. Any ornament, curtains or other signs shall not be placed in a place where the visibility of the exit signs may be obstruct.

What fire safety marks are needed for firefighting equipment?

“2005 regulatory reform (fire safety) Order” thirteenth provisions: any non-automatic fire protection equipment is easy to use, the mark is clear. The signs used are as follows:

  • Fire Extinguisher Sign: displayed next to all fire extinguishers to easily identify the location of the nearest extinguisher.
  • Fire Alarm Call Point Sign: located at all fire alarms.
  • Fire Hose Reel Sign: located at all fire hose points
  • Fire Blanket Sign: located at all fire blanked locations
  • In Case Of Fire. Do Not Use The Lift Sign: displayed at all lifts alongside the “Use Stairs” sign to indicate safe escape route.

What fire safety marks are needed for emergency exportation?

“The 2005 regulatory reform (fire safety) Order” fourteenth provisions, “emergency routes and exports must be marked by signs.” The signs used are as follows:

  • Fire Door Keep Shut Sign: displayed on each side of all fire doors to ensure safety.
  • Fire Exit Sign: displayed along all designated fire escape routes (with arrows) and above all emergency exits (without arrows).
  • Fire Assembly Point: a pictogram or written sign displayed at the outside point of assembly where people must gather after evacuation.
  • In Case Of Fire. Use Stairs Sign: an information sign displayed next to lifts and the top of staircases so people know not to use the lift for safety reasons.

Firefighting signs start from the direction arrow, showing the safest and fastest emergency route. Please note that the last fire channel sign above the emergency exit door does not display the direction arrow.